Tech Specs

Pure Power Plug-In Tech Specs: 
Highlights: 
  • 120 Volt Single Phase Electricity Coordinator
  • Unit Size 5.25" x 3.75" x 2"
  • Low Power Losses, <0.5 Watts per 1000 VAR
  • Operating Temperature Range of -55 degrees C to +90 degrees C
  • General Enclosure: Plug-In Unit
  • Circuit Zone Electrical Protection
  • Self-healing metalized Harmonic Rectifiers
  • NEMA 5-15 plug (two flat parallel blades with ground pin)
  • EMI/RFI Noise Reduction 0-50 dB
  • Power Factor Compensation
  • Voltage Moderation
  • Robust Integrated Surge Suppression
  • Electrical Harmonics Elimination (THD Reduction) 
  • EMF/EMR Elimination 

Characteristics: 

  • Max AC voltage (charge potential): 300 Volts
  • Single Phase Voltages Available: 120 Volts, USA (300 Volt L-N MAX)
  • Input Power Frequency: 50/60 Hz
  • Current Requirements @ 120 Volts: 0.85 Amps
  • Operating Temperature: -55 degrees C to +90 degrees C
  • Operating Humidity: 5% to 95%, Noncondensing
  • Operating Altitude: Up to 16,000 ft (5000m)
  • Seismic Withstanding Capability: (Meet or Exceed Specifications) IBC 2006, CBC 2007, & UBC Zone 4
Harmonic Rectifier Circuit Qualities: 
  • Total Unit Reactive Power @300V (L1-N): 20 uF
  • Per Circuit Reactive Power @300V (L1-N): 20 uF
  • Reactive Bank Composition: 6 PFC Modules
Harmonic Dissipations-PFC Module Specs: 
  • Tangent of Loss Angle: C>1. uF at 1 kHz: <=30*10^-4
  • Rated Voltage Pulse Slope (dV/dt); P=22.5mm: 150 V/us
  • RC Between Leads: >5000s
  • Withstanding (DC) Voltage (Cut-off Current 10 mA): 1850V
  • EMI/RMI Filtering Attenuation: Up to 50 dB from 10 kHz to 100 MHz
  • Protection Modes: (L1-L2 & L1-N & L2-N)
Surge Suppression: 
  • Voltage (Continuous) 250 Volts RMS, 424 Volts DC (Max Clamping) 650 Volts RMS. Transient Dissipation Potential Each Circuit (Surge Energy): 1300 Joules/us. Protection Modes (Single Circuit): L1-N
Description/Code: 
  • Made in Montana
  • Made in the USA
  • UL-E337361- Closed Energy Management Equipment 3ZJ9
  • FCC-Approved (UL Tested for Compliance)
  • CE-Low Voltage Directive 2006/95/EC
  • CE-Electromagnetic Compatibility (EMC) 2004/108/EC
  • RoHS-Lead Free-Restriction of Hazardous Substances

    Super Duty Power Perfect Box Tech Specs: 
    Highlights: 
    • 120/208, 120/240 Volt Single Split-Phase Electricity Conditioner
    • Low Power Losses, <0.5 Watts per 1000 VAr
    • Operating Temperature Range of -55 degrees C to +90 degrees C
    • General Enclosure: NEMA 3X Indoor/Outdoor
    • Electrical Harmonics Elimination (THD Reduction) 
    • Three-Way Electrical Protection
    • Self-healing metalized Harmonic Rectifiers
    • Robust Tri-Circuit Integrated Surge Protection
    • EMI/RFI Noise Reduction 0-50 dB
    • Wire Rating: 600 Volts, THHN/MTW,THWN-2
    • Box Size: 14" x 7.5" x 4" 
    • EMF/EMR Reduction
    • Voltage Moderation
    • Power Factor Compensation
    • Surge Suppression 
    Characteristics: 
    • Max AC Voltage (Charge Potential): 300 Volts
    • Single Split-Phase Voltages Available: 120/208, 120/240 Volts (300 Volt L1 to L2 MAX)
    • Input Power Frequency: 50/60 Hz
    • Wire Rating: 600 Volts, MTW/THHN/THWN-2
    • Current Requirements @120/208 Volts: L1 4.75 Amps. (Terminated to a Double Pole 15A Breaker) L2 4.75 Amps, N 1.88 Amps
    • Operating Temperature: -55 degrees C to +90 degrees C
    • Operating Humidity: 5% to 95%, Noncondensing
    • Operating Altitude: Up to 16,000 ft. (5000m)
    • Seismic Withstand Capability (Meet or Exceed Specifications): IBC 2006, CBC 2007 & UBC Zone 4
    Harmonic Rectifier Circuit Qualities: 
    • Total Unit Reactive Power @ 300 V (L1-L2 + L1-N+L2-N) + (L1-L2+L1-n+L2-N): 120 uF
    • Per Circuit Reactive Power @300 V (L1-L2 + L1-N+L2-N) + (L1-L2+L1-N+L2-N): 20 uF
    • Reactive Bank Composition: 36 PFC Modules
    Harmonic Dissipations-PFC Module Specs: 
    • Tangent of Loss Angle; C>1 uF at 1 kHz: <=30*10^-4
    • Rated Voltage Pulse Slope (dV/dt); P=22.5mm: 150 V/us
    • RC Between Leads: >5000s
    • Withstanding(DC) Voltage (Cut-off Current 10 mA): 1850V
    • EMI/RMI Filtering Attenuation: Up to 50 dB form 10 kHz to 100 MHz
    • Protection Modes: (L1-L2 & L1-N & L2-N) + (L1-L2 & L1-N & L2-N)
    Surge Suppression: 
    • Voltage (continuous) 250 Volts^RMS, 424 Volts^DC, (Max Clamping) 650 Volts^RMS
    • Current (Peak Surge) 6.5 kAmps (Rating) 6500 Amps
    • Transient Dissipation Potential Each Circuit (Surge Energy): 1300 Joules/us
    • Protection Modes (Dual Tri-Circuit Integration): (L1-L2 & L1-N & L2-N) + (L1-L2 & L1-N & L2-N)
    Description/Code: 
    • Made in Montana
    • Made in the USA
    • UL/CSA-E337361-Open Energy Management Equipment 3ZJ9
    • FCC-Approved (UL Tested for Compliance)
    • CE-Low Voltage Directive 2006/95/EC
    • CE-Electromagnetic Compatibility (EMC) 2004/108/EC
    • RoHS-Lead Free-Restriction of Hazardous Substances
    • Operating Voltage: 85 to 300 VAC
    • Operating Frequencies: 50 or 60 Hz
    • Voltage Reading: 85 to 250 +/-2 VAC
    • Instrument Line Noise Range: 0-2999 mV peak-to-peak
    • Instrument Sensitivity Range: 5 kHz-25MHz
    • Weighted Instrument Sensitivity Range: 10 kHz-10MHz
    • Display: Large 2.3" (easy to read) Graphic Backlit Display
    • Audio Feedback: Demodulated EMI noise
    • Physical: 4.7" x 3.1" x 1" (12 x 7.9 x 2.5 cm)
    LED Specifications: 
    • Driver: Dimmable
    • Voltage: 110-130V
    • THD: <1%
    • Rated Power: 9W
    • Power Factor: >.90
    • Beam Angle: 300 degrees
    • Lumens: 900
    • Color Temp: 2700K/4000K
    • CRI >85
      FieldShield consists of 8 Layers of Protection: 
      1. 99.9% Aluminum (a conductor)
      2. Closed-cell polyethylene foam (a resistor)
      3. 99.9% Aluminum (a conductor)
      4. A proprietary invisi-shield reflective blend of titanium dioxide, zinc, silver and ceramic
      5. YShield EMR Protection HSF54 paint
      6. 99.9% Aluminum (a conductor)
      7. Closed-cell polyethylene foam (a resistor)
      8. 99.9% Aluminum (a conductor) bonded together, having a grommet (creating continuity between all layers) and a cord for grounding